Basic Info.
Model NO.
D1-056
Fans Species
Single-speed Fan
Noise Level
Low
Application Fields
Chemical Industry
Certification
ISO
Condition
New
Product
Air Cooler
Capacity
4.89-649kw
Air Flow
2828-263503 M3/H
Fan
630
Power
400/3n/50Hz
Fan Brand
Ziehl-Abegg Fan
Fin Spacing
2.1 mm
Tcopper Tubes
12 or 16 mm
Casing
Galvanized Plate, Spray
Cooling Media
Water / Glycol Mixes and Others
Transport Package
Export Packaging
Specification
customized
Trademark
VENTTECH
Origin
Shanghai, China(Mainland)
HS Code
8415901000
Production Capacity
1500units Per Month
Product Description
hydrophilic aluminum fin district heating radiator dry cooler with inverter fan
Dry cooler Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
Dry Air Cooler Features:
1. Cooling capacity: 4.89-649kW
2. Fans: Maintenance free Ziehl-Abegg fans
3. Coil: aluminum fins 0,15 mm, copper tubes diameter 12 or 16 mm, fin spacing 2,1 mm
4. Casing: galvanized plate, spray
5. Cooling media: Water / glycol mixes and others
6. Air direction: Vertical or horizontal
Dry Air Cooler Options:
1. Coil design refrigerant: water, oil, glycol.
2. Multiple circuits.
3. Sub-cooling circuits.
4. Stainless steel or aluminum casing.
5. Coated aluminum or copper fins.
6. Explosion ploof motor.
7. Customized fin spacing.
Dry cooler D1 series parameter(fin space 2.1mm):
Dry cooler Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
Dry Air Cooler Features:
1. Cooling capacity: 4.89-649kW
2. Fans: Maintenance free Ziehl-Abegg fans
3. Coil: aluminum fins 0,15 mm, copper tubes diameter 12 or 16 mm, fin spacing 2,1 mm
4. Casing: galvanized plate, spray
5. Cooling media: Water / glycol mixes and others
6. Air direction: Vertical or horizontal
Dry Air Cooler Options:
1. Coil design refrigerant: water, oil, glycol.
2. Multiple circuits.
3. Sub-cooling circuits.
4. Stainless steel or aluminum casing.
5. Coated aluminum or copper fins.
6. Explosion ploof motor.
7. Customized fin spacing.
Air flow scheme | |
Performance ranges | Air cooled condensers capacity: from 148 to 921 kW *Airflow: from 76459 to 351663 m3/hDry coolers: customized on demand |
Coil features | High heat exchange efficiency. Designed with special "Air Intake" profile aluminum fins and inner grooved copper tubes, Copper tube 12.7mmFin spacing: 2,1 mm |
Casing features | galvanized plate, spray |
Fan motor features | Diameter: 630mmVoltage: 400V/3P/50HzFan brand: Ziehl-Abegg, can be customized on demand |
Testing | Heat exchanger are supplied clean and tested at a pressure of 3.0 Mpa. |
Dry cooler D1 series parameter(fin space 2.1mm):
Type | D1-502-12x630 | ||||||
Capacity | Water | 35ºC outdoor temp. | Inlet | 45ºC, | △ | KW | 502.25 |
outlet | 40ºC | Y | 405.20 | ||||
20% Glycol | Inlet | 45ºC | △ | 493.40 | |||
outlet | 40ºC | Y | 398.45 | ||||
Medium | Water flow | M3/h | 88 | ||||
Pressure drop | kPa | 97 | |||||
Air flow | △ | M3/h | 197326 | ||||
Y | 149612 | ||||||
Fan motor | Phase | 3 | |||||
△ | W | 33000 | |||||
Y | 21000 | ||||||
△ | A | 61.20 | |||||
Y | 36.00 | ||||||
Fan | No X φ | 2x6x630 | |||||
Sound pressure level | △ | dB(A) | 68 | ||||
Y | 10m | 61 | |||||
Dimension | L | mm | 8130 | ||||
W | mm | 2100 | |||||
H | mm | 1120 | |||||
A | mm | -- | |||||
B | mm | 1340 | |||||
C | mm | 1300 | |||||
D | mm | 640 | |||||
Inlet φ | mm | 2XDN125 | |||||
Inlet φ | mm | 2XDN125 | |||||
Product weight(empty) | kg | 2112 |